ORIGINAL ARTICLE
Effect of central dialysis fluid delivery system using high flux dialyzer versus regular water treatment stations on endotoxemia and inflammatory markers among prevalent patients on regular hemodialysis
More details
Hide details
1
Department of Nephrology, Faculty of Medicine, Ain-Shams University, Cairo, EGYPT
Publication date: 2024-05-30
Electron J Gen Med 2024;21(3):em591
KEYWORDS
ABSTRACT
Purpose:
In this study, we compared the effects of a single patient dialysis fluid delivery system (SPDDS) against
a central dialysis fluid delivery system (CDDS) on inflammatory markers and endotoxemia in a population of
patients receiving routine hemodialysis (HD).
Materials & methods:
80 prevalent HD patients, aged from 18 to 60 years old, who were clinically stable and
receiving thrice weekly dialysis treatments via an arteriovenous fistula were the subjects of a cross-sectional
research. group I underwent HD using a CDDS water purification system that was implemented at El Demerdash
Hospital two years prior, and group II underwent HD using an SPDDS water purification system at Ain Shams
Specialized Hospital.
Results:
Pre-dialysis endotoxin levels were significantly lower in the CDDS group (0.07±0.05) compared to the
SPDDS group (0.20±0.07), p-value<0.001, post-dialysis serum endotoxin levels were significantly lower in CDDS
group (0.04±0.02) compared to SDDPS (0.15±0.03), p-value<0.001.
Conclusions:
CDDS group’s circulating endotoxins had significantly decreased.
REFERENCES (19)
1.
Sohrabi Z, Eftekhari MH, Eskandari MH, Rezaeianzadeh A, Sagheb MM. Malnutrition-inflammation score and quality of life in hemodialysis patients: Is there any correlation? Nephrourol Mon. 2015;7(3):e27445.
https://doi.org/10.5812/numont... PMid:26034747.
2.
Mendoza JM, Isakova T, Cai X, et al. Inflammation and elevated levels of fibroblast growth factor 23 are independent risk factors for death in chronic kidney disease. Kidney Int. 2017;91(3):711-9.
https://doi.org/10.1016/j.kint... PMid:28017325 PMCid:PMC5313324.
3.
Bakaloudi DR, Siargkas A, Poulia KA, Dounousi E, Chourdakis M. The effect of exercise on nutritional status and body composition in hemodialysis: A systematic review. Nutrients. 2020;12(10):3071.
https://doi.org/10.3390/nu1210... PMid:33050111 PMCid:PMC7601723.
4.
Hsu C-C, Wei T-S, Huang C-C, Chen Y-M. Endotoxemia is associated with acute coronary syndrome in patients with end stage kidney disease. BMC Nephrol. 2017;18(1):235.
https://doi.org/10.1186/s12882... PMid:28701158 PMCid:PMC5508664.
5.
Yamashita T, Yoshida N, Emoto T, Saito Y, Hirata K-I. Two gut microbiota-derived toxins are closely associated with cardiovascular diseases: A review. Toxins (Basel). 2021;13(5):297.
https://doi.org/10.3390/toxins... PMid:33921975 PMCid:PMC8143486.
6.
Mohammad S, Thiemermann C. Role of metabolic endotoxemia in systemic inflammation and potential interventions. Front Immunol. 2021;11:594150.
https://doi.org/10.3389/fimmu.... PMid:33505393 PMCid:PMC7829348.
7.
Kawanishi H, Moriishi M, Takahashi N, Tsuchiya S. The central dialysis fluid delivery system (CDDS): Is it specialty in Japan? Ren Replace Ther. 2016;2:1.
https://doi.org/10.1186/s41100....
8.
Masakane I, Kawanishi H, Mineshima M, et al. 2011 JSDT standard on the management of endotoxin retentive filter for dialysis and related therapies. Ther Apher Dial. 2013; 17(2):229-40.
https://doi.org/10.1111/1744-9... PMid:23551680.
9.
Koda Y, Mineshima M. Advances and advantages in recent central dialysis fluid delivery system. Blood Purif. 2009;27(1):23-7.
https://doi.org/10.1159/000213... PMid:19556760.
10.
Douvris A, Zeid K, Hiremath S, et al. Mechanisms for hemodynamic instability related to renal replacement therapy: A narrative review. Intensive Care Med. 2019; 45(10):1333-46.
https://doi.org/10.1007/s00134... PMid:31407042 PMCid:PMC6773820.
11.
Hasegawa T, Nakai S, Masakane I, et al. Dialysis fluid endotoxin level and mortality in maintenance hemodialysis: A nationwide cohort study. Am J Kidney Dis. 2015;65(6):817-9.
https://doi.org/10.1053/j.ajkd... PMid:25641063.
12.
Ibrahim M, Behairy M, El-Ashry M, Mostafa AE. Cardiovascular risk of circulating endotoxin level in prevalent hemodialysis patients. Egypt Heart J. 2018;70(1);27-33.
https://doi.org/10.1016/j.ehj.... PMid:29622994 PMCid:PMC5883510.
13.
McIntyre CW, Harrison LEA, Eldehni MT, et al. Circulating endotoxemia: A novel factor in systemic inflammation and cardiovascular disease in chronic kidney disease. Clin J Am Soc Nephrol. 2011;6(1):133-41.
https://doi.org/10.2215/CJN.04... PMid:20876680 PMCid:PMC3022234.
14.
Kwan BC-H, Chow K-M, Ma TK-W, et al. Effect of using ultrapure dialysate for hemodialysis on the level of circulating bacterial fragment in renal failure patients. Nephron Clin Pract. 2013;123(3-4):246-53.
https://doi.org/10.1159/000354... PMid:24008429.
15.
Elsayed H, Anwar W, Ahmed H, Khedr L. Cytokine inducing substances (CIS): Effect of back filtration on inflammatory indices in hemodialysis. In: ISN World Congress of Nephrology. Mexico City: Sustainability and Diversity.
16.
den Hoedt CH, Bots ML, Grooteman MPC, et al. Online hemodiafiltration reduces systemic inflammation compared to low-flux hemodialysis. Kidney Int. 2014;86(2): 423-32.
https://doi.org/10.1038/ki.201... PMid:24552852.
17.
Elsayed HM, Mahmoud BL, Hassan MS, Moustafa AM. Effect of central dialysis fluid delivery system (CDDS) on IL6 & CRP levels in prevalent haemodialysis patients. Int J Med. 2021;114(1).
https://doi.org/10.1093/qjmed/....
18.
Susantitaphong P, Riella C, Jaber BL. Effect of ultrapure dialysate on markers of inflammation, oxidative stress, nutrition, and anemia parameters: A meta-analysis. Nephrol Dial Transplant. 2013;28(2):438-46.
https://doi.org/10.1093/ndt/gf... PMid:23291370.
19.
Rahmati MA, Homel P, Hoenich NA, Levin R, Kaysen GA, Levin NW. The role of improved water quality on inflammatory markers in patients undergoing regular dialysis. Int J Artif Organs. 2004;27(8):723-7.
https://doi.org/10.1177/039139... PMid:15478544.